Private Mold: | Yes | Products Status: | Stock |
---|---|---|---|
Highlight: | OEM unity xt880,unity xt880 Array,dell emc unity xt 480 Array |
|
380F/380
|
480F/480
|
680F/680
|
880F/880
|
Min/Max Drive Count
|
Min. 6 SSDs or 10 HDDs /
Max. 500 |
Min. 6 SSDs or 10 HDDs /
Max. 750 |
Min. 6 SSDs or 10 HDDs /
Max. 1000 |
Min. 6 SSDs or 10 HDDs /
Max. 1500 |
Array Enclosure
|
A 2U Disk Processor Enclosure (DPE) with twenty-five 2.5” drives
|
|||
Drive Enclosure (DAE -
Disk Array Enclosure) |
All-Flash (F) models support 2.5” drives in the 2U twenty-five drive tray.
Hybrid models support 2.5“drives in 2U twenty-five drive and 3.5” drives in 3U fifteen drive trays.
|
|||
Standby Power System
|
Dell Unity systems are powered by 2 power supplies (PS) per DPE/DAE. Each power supply can provide power to
the entire module if the peer PS has been removed or is faulted. DPE power during a power failure is provided by a
Battery Back Up (BBU) module. BBU is located within the SP enclosure and provides power to a single module
(power zone)
|
|||
RAID Options
|
1/0, 5, 6
|
|||
CPU per Array
|
2 x Intel CPUs, 12 cores
per Array, 1.7GHz |
2 x dual-socket Intel
CPUs, 32 cores per Array, 1.8GHz |
2 x dual-socket Intel
CPUs, 48 cores per Array, 2.1GHz |
2 x dual-socket Intel CPUs
64 cores per Array, 2.1GHz |
System Memory/Cache
per Array |
128 GB
|
192 GB
|
384 GB
|
768 GB
|
Max FAST Cache
Array* |
Up to 800 GBs
|
Up to 1.2 TBs
|
Up to 3.2 TBs
|
Up to 6.0TBs
|
Total CacheA
|
Up to 928 GBs
|
Up to 1.39 TBs
|
Up to 3.58 TBs
|
Up to 6.76 TBs
|
Max Mezzanine cards per
ArrayB |
NA
|
2
|
2
|
2
|
Max IO Modules
ArrayC |
4
|
4
|
4
|
4
|
Embedded SAS IO Ports
per Array |
4 x 4 lane 12Gb/s SAS
ports for BE (back end) Connection |
4 x 4 lane 12Gb/s SAS
ports for BE Connection |
4 x 4 lane 12Gb/s SAS
ports for BE Connection |
4 x 4 lane 12Gb/s SAS
ports for BE Connection |
Spec Sheet
|
380F/380
|
480F/480
|
680F/680
|
880F/880
|
Optional SAS IO
Array |
NA
|
8 x 4 lane or 4 x 8 lane
12Gb/s SAS ports (for BE Connection) |
8 x 4 lane or 4 x 8 lane
12Gb/s SAS ports (for BE Connection) |
8 x 4 lane or 4 x 8 lane
12Gb/s SAS ports (for BE Connection) |
Base 12 Gb/s SAS BE
Buses per Array |
2 x 4 Lane
|
2 x 4 Lane
|
2 x 4 Lane
|
2 x 4 Lane
|
Max 12 Gb/s SAS BE
Buses per Array |
2 x 4 Lane
|
6 x 4 Lane; or 2 x 4 lane
and 2 x 8 lane |
6 x 4 Lane; or 2 x 4 lane
and 2 x 8 lane |
6 x 4 Lane; or 2 x 4 lane
and 2 x 8 lane |
Max FE (front end) Total
Ports per Array (all types) |
20
|
24
|
24
|
24
|
Max Initiators per Array
|
1,024
|
2,048
|
2,048
|
4,096
|
Max FC Ports per Array
|
20
|
16
|
16
|
16
|
Embedded 10GbaseT
Ports per Array |
NA
|
NA
|
NA
|
NA
|
Embedded CNA
Array |
4 ports: 8/16 Gb FCD ,
10Gb IP/iSCSI, or 1Gb RJ45 |
NA
|
NA
|
NA
|
1 Gbase-T/iSCSI Max
Total Ports per Array |
20
|
24
|
24
|
24
|
10/25 GbE/iSCSI Max
Total Ports per Array |
20 – 10GbE
16 – 25GbE |
24
|
24
|
24
|
Max Raw CapacityE
|
2.4 PBs
|
4.0 PBs
|
8.0 PBs
|
16.0 PBs
|
Max SAN Hosts
|
512
|
1,024
|
1,024
|
2,048
|
Max Number of Pools
|
20
|
30
|
40
|
100
|
Max Number of LUNs
Array |
1,000
|
1,500
|
2,000
|
6,000
|
Max LUN Size
|
256 TB
|
256 TB
|
256 TB
|
256 TB
|
Max File Systems per
Array |
1000
|
1500
|
2000
|
4000
|
Max File System Size
|
256 TB
|
256 TB
|
256 TB
|
256 TB
|
Max attached snapshots
per Array (Block) |
1000
|
1500
|
2000
|
6000
|
IOPSF (All Flash Models
380F – 880F) |
up to 600K
|
up to 1.68M
|
up to 2.36M
|
up to 2.56M
|
OS Support
|
See the Dell Simple Support Matrix on dell.com
|
|
380F/380
DPE 25 2.5” SFF drives and four IO modules |
480F/480
DPE 25 2.5” SFF drives and four IO modules |
680F/680*
DPE 25 2.5” SFF drives and four IO modules |
880F/880
DPE 25 2.5” SFF drives and four IO modules |
POWER
|
|
|
|
|
AC Line Voltage
|
100 to 240 VAC ± 10%, single phase, 47 to 63 Hz
|
|||
AC Line Current
(operating maximum) |
10.07 A max at 100 VAC;
5.04 A max at 200VAC |
10.6 A max at 100 VAC;
5.3 A max at 200VAC |
11.72 A max at 100 VAC;
5.86 A max at 200VAC |
14.41 A max at 100 VAC;
7.2 A max at 200VAC |
|
25 X 2.5” Drive DAE
|
15 X 3.5” Drive DAE
|
||
POWER
|
||||
AC Line Voltage
|
100 to 240 VAC ± 10%, single phase, 47 to 63 Hz
|
|||
AC Line Current
(operating maximum) |
4.50 A max at 100 VAC,
2.40 A max at 200 VAC |
2.90 A max at 100 VAC,
1.60 A max at 200 VAC |
||
Power Consumption
(operating maximum) |
453.0 VA/ 432.0 W max at 100 VAC
485.0 VA/ 427.0 W max at 200VAC |
287.0 VA/ 281.0 W max at 100 VAC
313.0 VA/ 277.0 W max at 200VAC |
||
Power Factor
|
0.95 minimum at full load, @ 100V/200V
|
0.90 minimum at full load, @ 100V/200V
|
||
Heat Dissipation
(operating maximum) |
1.56 x 106 J/hr, (1,474 Btu/hr) max at 100 VAC
1.54 x 106 J/hr, (1,457 Btu/hr) max at 200 VAC |
1.01 x 106 J/hr, (959 Btu/hr) max at 100 VAC
1.00 x 106 J/hr, (945 Btu/hr) max at 200 VAC |
||
In-rush Current
|
30 Apk “cold” per line cord, at any line voltage
|
30 A max “cold” for ½ line cycle, per line cord at 240
VAC |
||
Startup Surge Current
|
40 Apk “cold” per line cord, at any line voltage
|
25 Amps peak max per line cord, at any line voltage
|
||
AC Protection
|
15 A fuse on each power supply, single line
|
10 A fuse on each power supply, single line
|
||
AC Inlet Type
|
IEC320-C14 appliance coupler, per power zone
|
|||
Ride-through Time
|
12 ms minimum
|
30 ms minimum
|
||
Current Sharing
|
± 5 percent of full load, between power supplies
|
Droop Load Sharing
|
||
WEIGHT AND DIMENSIONS
|
||||
Weight kg/lbs
|
Empty: 10.0/22. 1
Full: 20.23/44.61 |
Empty: 14.5/32
Full: 30.8/68 |
||
Vertical size
|
2 NEMA units
|
3 NEMA units
|
||
Height cm/inches
|
8.46/3.40
|
13.33/5.25
|
||
Width cm/inches
|
44.45/17.5
|
44.45/17.5
|
||
Depth cm/inches
|
33.02/13
|
35.56/14
|